Mar 17, 2026 Tso lus

Yuav Ua Li Cas Pom SF6 Gas Leakage hauv High Voltage Circuit Breakers?

Cia kuv pib nrog zaj dab neeg nrawm. Ob peb xyoos dhau los, kuv tau txais kev hu xov tooj los ntawm lub chaw nres tsheb substation hais txog lub tshuab hluav taws xob uas tau tripped ntawm cov pa roj tsawg. Thaum kuv mus txog qhov ntawd, lub ntsuas ntsuas yuav luag xoom. Peb pib yos hav zoov rau qhov xau - xav tias nws yuav pom tseeb. Tab sis tom qab ob teev nrog tus sniffer, tsis muaj dab tsi. Tig tawm lub xau yog nyob rau hauv qab ntawm ib tug bushing, muab zais nyob rau hauv ib txheej ntawm cov roj qub thiab hmoov av. Hnub ntawd tau qhia kuv ib zaj lus qhia: nrhiav SF6 xau ntau npaum li kev ua siab ntev thiab paub koj cov cuab yeej zoo li nws yog hais txog cov cuab yeej zoo nkauj.

 

Yog tias koj ua haujlwm nroghigh voltage breakers, koj twb paub SF6 tsis yog ib yam dab tsi koj mess nrog. Nws hnyav, nws kim heev, thiab nws yog lub tsev cog khoom roj nrog lub ntiaj teb ua kom sov siab tsis zoo. Qhov tseem ceeb tshaj, thaum nws xau, koj lub breaker poob nws lub peev xwm los cuam tshuam kev ua txhaum. Yog li cas koj yuav nrhiav tau cov dej ntws ua ntej lawv ua teeb meem? Nov yog qhov ua haujlwm rau kuv ntau xyoo.

 

Pib Nrog Cov Hauv Paus: Cov Kev Ntsuas Siab thiab Qhov Ntsuas

 

Txhua lub tshuab hluav taws xob niaj hnub tsim nyog los nrog qhov hloov ceev los yog ntsuas qhov ntsuas kub uas yog qhov kub thiab txias - them nyiaj. Nov yog koj thawj kab ntawm kev tiv thaiv. Tab sis ntawm no yog qhov - Kuv tau pom cov neeg ua haujlwm tsis quav ntsej qhov poob qis rau lub hlis vim lawv xav tias "nws tsuas yog qhov ntsuas kub hloov pauv xwb." Ib lub ntsuas ntsuas ntsuas ntsuas kub tawm ntawm qhov sib npaug. Yog hais tias qhov kev nyeem ntawv yog trending down, koj muaj ib tug leak. Lub sijhawm.

 

Feem ntau cov breakers muaj ob theem tswb. Thawj lub tswb feem ntau ncaws nyob ib ncig ntawm 5-10% hauv qab nominal. Qhov ntawd yog koj li sawv- hu. Lub tswb thib ob tuaj yeem kaw lub breaker tawm. Koj tsis xav li ntawd. Yog li txuas cov tswb no rau SCADA. Kev cia siab rau ib tus neeg taug kev los ntawm kev nyeem ntawv ntsuas yog zoo li tso siab rau lub ntsuas pa taws tsis muaj roj teeb.

 

Tus Neeg Zoo Qub Sniffer - Tseem Tus Ua Haujlwm

 

Handheld electronic leak detectors yog yam uas peb feem coob siv niaj hnub no. Lawv ua haujlwm los ntawm hnia rau SF6 molecules - qee qhov siv corona tawm, lwm tus siv infrared nqus. Tsis muaj teeb meem ntau npaum li cas cov cuab yeej siv ntev npaum li lub tsev tau nkag siab tsawg kawg 1 ppm.

 

Tab sis muaj ib tug ua kom yuam kev siv lawv txoj cai. SF6 yog rau lub sij hawm hnyav dua huab cua, yog li nws tog. Qhov ntawd txhais tau tias koj pib rau saum lub breaker thiab ua haujlwm koj txoj hauv kev. Flanges, valve stems, ntsuas kev sib txuas, nyob qhov twg muaj lub gasket lossis xov. Kuv nyiam txav qhov kev sojntsuam qeeb - txog ib nti ib ob - vim tias yog koj zip nrog, koj yuav nco txog qhov xau me me.

 

Thiab thov, ntsuas qhov khoom txhua xyoo. Ib zaug kuv tau siv tus sniffer uas tsis muaj qhov ntsuas qhov ntsuas uas tsis pom muaj dab tsi ntawm lub tshuab hluav taws xob uas tau pom tseeb poob roj. Muab tawm nws tau nyeem ib nrab ntawm qhov nws yuav tsum muaj. Kev ntxhov siab tsis pib piav txog nws.

 

Why sf6 circuit breaker is used?

 

Soap Spray - Yooj yim thiab ntseeg tau

 

Yog hais tias lub breaker yog de{0}}energized thiab koj tuaj yeem tau txais kev sib txuas, dej xab npum tseem yog ib txoj hauv kev zoo tshaj plaws. Muab cov xab npum me me nrog dej hauv lub raj mis tsuag, muab ib co zoo, thiab tshuaj tsuag txhua qhov chaw. Leaks yuav tshuab npuas. Nws yog qhov ncaj ncaj.

 

Tab sis muaj ib txoj kev yog thiab txoj kev tsis ncaj ncees lawm. Tsis txhob siv txhuam hniav - nws tawm cov kua ntau dhau thiab koj tuaj yeem tsis ua npuas ua npuas. Txau ib qho pos nphuab thiab saib ze. Thiab tsis txhob tsuag energized qhov chaw, obviously. Qhov ntawd yog qhov kev pheej hmoo poob siab thiab luv luv tos kom tshwm sim.

 

Kuv tau pom cov xab npum ua haujlwm zoo ntawm cov xov fittings thiab cov Schrader li qub me me uas txhua tus tsis nco qab txog. Cov li qub no tuaj yeem xau txaus los tso siab dhau ib xyoos. Kev txhaj tshuaj sai ntawm xab npum qhia nws tam sim ntawd.

 

Ultrasonic - Thaum koj tsis tuaj yeem kaw

 

Qee lub sij hawm koj yuav tsum tau kuaj xyuas cov dej xau thaum lub iav nyob, lossis koj tsuas yog xav luam theej duab thaj tsam loj. Ultrasonic detectors khaws lub siab -ntau zaus ntawm cov pa khiav tawm. Lawv tsis meej npaum li tus sniffer - koj yuav tsis pom qhov tseeb pinhole - tab sis lawv yuav qhia koj "muaj ib yam dab tsi dhau ntawm lub ces kaum."

 

Kuv khaws lub ntsuas ntsuas ultrasonic hauv kuv lub tsheb kom taug kev nrawm- nqes. Muab lub mloog pob ntseg, cheb thaj chaw, thiab mloog cov suab nrov ntawd. Nws yog amazing li cas ib tug leak koj tsis hnov ​​nrog koj liab qab pob ntseg yuav pom tseeb los ntawm lub headphones.

 

Lub Koob Yees Duab Infrared - Tus Qauv Kub

 

Yog tias koj tau txais cov peev nyiaj, lossis koj tuaj yeem xauj ib qho rau ib hnub, lub koob yees duab kho qhov muag pom kev pom zoo rau nws qhov hnyav kub. Cov koob yees duab no pom SF6 ua lub plume dub tiv thaiv keeb kwm yav dhau. Koj tuaj yeem sawv ntsug 30 feet deb thiab saib cov pa tawm ntawm lub flange uas koj tsis tuaj yeem ncav cuag.

 

Kuv nco ntsoov thawj zaug uas kuv siv ib qho - peb pom peb qhov xau hauv kaum feeb uas tau eluding peb rau lub hlis. Ib qho yog tom qab lub txee tswj, lwm qhov nyob rau sab saum toj ntawm lub hav txwv yeem uas nag tau ntxuav tawm cov cim qhia. Lub koob yees duab tsis dag. Qhov downside? Lawv raug nqi ntau npaum li lub tsheb me. Yog li tshwj tsis yog tias koj cov nqi hluav taws xob muaj cov hnab tshos sib sib zog nqus, koj yuav zoo dua los xauj ib xyoos ib zaug rau kev soj ntsuam tag nrho.

 

What is the difference between SF6 circuit breaker and vacuum circuit breaker?

 

Tsim kom muaj Kev Tshawb Fawb Txog Kev Tshawb Fawb

 

Random checks yuav tsis txiav nws. Nov yog qhov kuv pom zoo raws li qhov ua haujlwm ntawm kuv cov nroj tsuag:

  • Txhua hli: Sau txhua qhov kev nyeem ntawv siab - tsis yog ntsia nws xwb, tab sis sau cia. Muab piv rau lub hli tas los. Ib qho kev poob qis ntawm 0.1 bar dhau peb lub hlis txhais tau tias muaj qhov xau, txawm tias nws me me.
  • Peb lub hlis twg: Coj tus sniffer thiab ua ib puag ncig ntawm tag nrho cov ntsiab lus nkag tau. Ua ib daim ntawv txheeb xyuas kom koj tsis txhob hla dab tsi.
  • Txhua xyoo: Yog tias koj ua tau, nqa lub koob yees duab IR rau kev tshuaj ntsuam xyuas kom meej. Lossis ua qhov kev ntsuas siab- poob los ntawm kev cais cov pa roj thiab saib xyuas dhau 24 teev.
  • Tom qab ib qho kev kho: Ib txwm, nco ntsoov rov xyuas txhua qhov kev sib txuas uas koj tau kov. Gaskets khoov, bolts loosen. Kuv tsis tuaj yeem qhia koj tias pes tsawg zaus kuv tau pom qhov "kho" breaker leaker vim tias ib tug neeg tsis kaw qhov haum kom zoo.

 

Dab tsi yog Qhov Txais Leak Rate?

 

Cov neeg tsim khoom feem ntau lav tsawg dua 0.5% hauv ib xyoos. Tab sis nyob rau hauv lub ntiaj teb no tiag tiag, "tau txais" nyob ntawm seb qhov kev cuam tshuam tseem ceeb npaum li cas. Ntawm kev sib kis loj, txawm tias 0.1% yog ntau dhau yog tias nws tab tom nce. Ntawm lub feeder uas tsis hnyav hnyav, koj tuaj yeem zam qhov kev quaj me me kom txog rau thaum qhov hluav taws xob tom ntej.

Qhov teeb meem tiag tiag yog ib puag ncig. SF6 yog lub tsev cog khoom muaj zog, thiab cov kev cai nruj nruj. Hauv qee qhov chaw, koj yuav tsum tau tshaj tawm cov dej xau saum toj ib qho loj. Yog li tsis txhob rub tawm ib qho me me - kho nws thaum koj ua tau.

 

Cov Pitfalls uas kuv tau pom (thiab ua)

 

  • Ib qho: Xav tias yog lub ntsuas ntsuas nyeem zoo, tsis muaj qhov xau. Tsis yog. Kev xau qeeb yuav siv sij hawm ntau lub hlis los nthuav tawm ntawm qhov ntsuas, tshwj xeeb tshaj yog tias koj tsis them nyiaj rau qhov kub thiab txias.
  • Thib ob: Ntxiv roj es tsis txhob nrhiav cov pa tawm. Topping tawm tsuas yog ncua lub inevitable.
  • Peb: Piv txwv li ib tug tshiab breaker yuav tsis xau. Kuv tau pom cov khoom lag luam- tshiab nrog cov khoom siv xoob los ntawm lub Hoobkas.
  • Ib qho ntxiv: siv cov tshuaj tua kab mob uas muaj cov tshuaj chlorine lossis lwm yam tshuaj uas tuaj yeem tua cov ntsaws ruaj ruaj. Lo rau cov xab npum thiab dej los yog cov khoom pom zoo.

 

Thaum twg Hu rau thaub qab

 

Yog tias koj tau ua txhua yam - sniffer, xab npum, ultrasonic - thiab tseem tsis tuaj yeem pom qhov xau uas koj paub tias muaj (vim tias koj poob roj), nws yog lub sijhawm hu rau qhov zoo. Cov tuam txhab nrog IR koob yees duab feem ntau tuaj yeem pom nws hauv ib teev. Tus nqi ntaus refilling lub breaker txhua xyoo thiab vam tias qhov zoo tshaj plaws.

Cov kab hauv qab: Nrhiav SF6 leaks yog ib feem ntawm kev tshawb nrhiav, ib feem ntawm kev saib xyuas. Cov cuab yeej muaj nyob ntawd - koj tsuas yog yuav tsum siv lawv txoj cai, thiab tsis txhob txiav cov ces kaum. Vim hais tias thaum tus breaker yuav tsum tau mus, koj xav kom nws ua hauj lwm. Tsis txhob zaum ntawd nrog roj tsawg, tos kom poob.

 

 

Yog tias koj muaj kev xav tau rauSF₆ Circuit Court breakers, txawm tias koj xav tau kev taw qhia kev, kev txhawb nqa khoom siv, lossis kev ua haujlwm thiab kev kho kom zoo, thov hu rau kuv. Kuv yuav ua hauj lwm rau koj tag nrho lub siab thiab xyuas kom koj muaj kev txaus siab. Nrhiav rau pem hauv ntej los ua haujlwm nrog koj los tsim kom muaj kev nyab xeeb thiab muaj txiaj ntsig zoo dua.
Email: luna@yawei-electric.com
WhatsApp: +86 15206275931

Xa kev nug

whatsapp

Xov tooj

Tug

Kev nug